ZHCST08A December 2022 – September 2023 TAS6424R-Q1
PRODUCTION DATA
The Channel State Reporting register is shown in Figure 9-26 and described in Table 9-22.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| CH1 STATE REPORT | CH2 STATE REPORT | CH3 STATE REPORT | CH4 STATE REPORT | ||||
| R-01 | R-01 | R-01 | R-01 | ||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7–6 | CH1 STATE REPORT | R | 01 | 00: PLAY 01: Hi-Z 10: MUTE 11: DC load diagnostics |
| 5–4 | CH2 STATE REPORT | R | 01 | 00: PLAY 01: Hi-Z 10: MUTE 11: DC load diagnostics |
| 3–2 | CH3 STATE REPORT | R | 01 | 00: PLAY 01: Hi-Z 10: MUTE 11: DC load diagnostics |
| 1–0 | CH4 STATE REPORT | R | 01 | 00: PLAY 01: Hi-Z 10: MUTE 11: DC load diagnostics |