ZHCSPX3A October 2022 – November 2022 TMUX7436F
PRODMIX
請(qǐng)參考 PDF 數(shù)據(jù)表獲取器件具體的封裝圖。
Fault flag recovery time (tRECOVERY(FLAG)) measures the delay between the source voltage falling from overvoltage condition to below fault supply voltage (VDD or VSS) plus 0.5 V and the general fault flag (FF) pin to rise above 3 V with 5 V external pull-up. Figure 7-12 shows the setup used to measure tRECOVERY(FLAG).