ZHCSZ39A September 2025 – December 2025 DRV81646
PRODUCTION DATA
| 參數(shù) | 測(cè)試條件 | 最小值 | 典型值 | 最大值 | 單位 | |
|---|---|---|---|---|---|---|
| 電源 | ||||||
| IVM | VM 工作電源電流 | VM = 24V,無(wú)開(kāi)關(guān) | 3 | mA | ||
| VM = 24V,輸出開(kāi)關(guān)頻率為 200kHz | 5 | mA | ||||
| VUVLO | VM 欠壓鎖定電壓 | VM 上升 | 4.1 | 4.25 | 4.45 | V |
| VM 下降 | 4.0 | 4.15 | 4.35 | V | ||
| VUVLO_HYS | VM 欠壓鎖定遲滯 | 100 | mV | |||
| tUVLO | VM 欠壓抗尖峰脈沖 | 10 | μs | |||
| 邏輯電平輸入(INx、nSCS、SCLK、SDI) | ||||||
| VIL | 輸入低電壓 | 0.8 | V | |||
| VIH | 輸入高電壓 | 2 | V | |||
| VHYS | 輸入遲滯 | 0.4 | V | |||
| IIL | 輸入低電流 | VIN = 0 | -5 | 5 | μA | |
| IIH | 輸入高電流 | VIN = 3.3V | 50 | 100 | μA | |
| 開(kāi)漏輸出(nFAULT、SDO) | ||||||
| VOL | nFAULT、SDO 的輸出低電壓 | IO = 5mA | 0.1 | V | ||
| IOH | nFAULT、SDO 的輸出高漏電流 | 上拉電阻至 5V | 1 | μA | ||
| tnFAULT_VALID | VVM > VUVLO(上升)后 nFAULT 信號(hào)有效的時(shí)間。 | 30 | μs | |||
| 七電平輸入 (RSLEW/CNTL) | ||||||
| VLVL1 | 第 1 級(jí),共 7 級(jí) | 連接至 GND | 0 | 0.1 | V | |
| VLVL2 | 第 2 級(jí),共 7 級(jí) | 14.7k? ± 5% 至 GND | 0.2 | 0.35 | V | |
| VLVL3 | 第 3 級(jí),共 7 級(jí) | 44.2k? ± 5% 至 GND | 0.55 | 0.8 | V | |
| VLVL4 | 第 4 級(jí),共 7 級(jí) | 100k? ± 5% 至 GND | 1 | 1.25 | V | |
| VLVL5 | 第 5 級(jí),共 7 級(jí) | 249k? ± 5% 至 GND | 1.5 | 1.75 | V | |
| VLVL6 | 第 6 級(jí),共 7 級(jí) | 高阻態(tài) | 2.1 | 2.4 | V | |
| VLVL7 | 第 7 級(jí),共 7 級(jí) | 連接至 DVDD(邏輯電壓) | 3 | 5 | V | |
| IRSLEW/CNTL | 輸入電流 | 22.5 | μA | |||
| SWITCHING | ||||||
| tR | 上升時(shí)間 OUTx 從 10% 上升到 90% VM = 24V,RL = 48Ω,CL = 0.1nF |
RSLEW/CNTL 上的 VLVL1 | 100 | 150 | ns | |
| RSLEW/CNTL 上的 VLVL6 或 VLVL7 | 300 | 450 | ns | |||
| RSLEW/CNTL 上的 VLVl4 或 VLVL5 | 700 | 1000 | ns | |||
| RSLEW/CNTL 上的 VLVL2 或 VLVL3 | 1500 | 2300 | ns | |||
| tF | 下降時(shí)間 OUTx 從 90% 下降到 10% VM = 24V,RL = 48Ω,CL = 0.1nF |
RSLEW/CNTL 上的 VLVL1 | 100 | 150 | ns | |
| RSLEW/CNTL 上的 VLVL6 或 VLVL7 | 300 | 450 | ns | |||
| RSLEW/CNTL 上的 VLVl4 或 VLVL5 | 700 | 1000 | ns | |||
| RSLEW/CNTL 上的 VLVL2 或 VLVL3 | 1500 | 2300 | ns | |||
| tPD | 輸入至輸出傳播延遲 INx 上升至高于 VIH,到 OUTx 下降至 90%,或 INx 下降至低于 VIL ,到 OUTx 上升至 10% VM = 24V;RL = 48Ω CL = 0.1nF |
RSLEW/CNTL 上的 VLVL1 | 100 | 150 | ns | |
| RSLEW/CNTL 上的 VLVL6 或 VLVL7 | 250 | 370 | ns | |||
| RSLEW/CNTL 上的 VLVl4 或 VLVL5 | 400 | 600 | ns | |||
| RSLEW/CNTL 上的 VLVL2 或 VLVL3 | 700 | 1000 | ns | |||
| 驅(qū)動(dòng)器輸出(OUTx) | ||||||
| RDS(ON) | FET 導(dǎo)通電阻 | VM = 24V,IO = 500mA,TJ = 25°C | 140 | m? | ||
| VM = 24V,IO = 500mA,TJ = 85°C | 225 | m? | ||||
| IOFF | 關(guān)斷狀態(tài)漏電流 | VOUT = VM = 24V | 0.5 | μA | ||
| IOFF | 關(guān)斷狀態(tài)漏電流 | VOUT = VM = 65V | 10 | μA | ||
| VF | 續(xù)流二極管正向電壓 | VOUT = 24V,IO = 500mA | 1.2 | V | ||
| IOFF | 再循環(huán)二極管反向漏電流 | VOUT = 0V,VCLAMP = 65V | 10 | μA | ||
| 保護(hù)電路 | ||||||
| ILIM | 電流限制值 遵循 60/RILIM[kΩ](30kΩ ≤ RILIM ≤ 120kΩ) |
RILIM 短接至 GND 或 RILIM < 20kΩ | 3 | A | ||
| RILIM = 30kΩ | 1.4 | 2 | 2.6 | A | ||
| RILIM = 60kΩ | 0.7 | 1 | 1.3 | A | ||
| RILIM = 90kΩ | 0.4 | 0.66 | 0.9 | A | ||
| RILIM = 120kΩ | 0.3 | 0.5 | 0.7 | A | ||
| ILIM_ACTIVATE | 電流限制激活閾值 遵循 ILIM+50% |
RILIM = 接地短路 | 4.7 | A | ||
| RILIM = 30kΩ | 3 | A | ||||
| RILIM = 60kΩ | 1.5 | A | ||||
| RILIM = 90kΩ | 1 | A | ||||
| RILIM = 120kΩ | 0.75 | A | ||||
| IINRUSH | tINRUSH 期間的電流限制值 遵循 2*ILIM[kΩ](RILIM≥40kΩ) |
RILIM = 接地短路 | 4 | A | ||
| RILIM = 30kΩ | 4 | A | ||||
| RILIM = 60kΩ | 1.4 | 2 | 2.6 | A | ||
| RILIM = 90kΩ | 0.8 | 1.2 | 1.6 | A | ||
| RILIM = 120kΩ | 0.6 | 1 | 1.4 | A | ||
| IINRUSH_ACTIVATE | 浪涌期間的電流限制激活閾值 遵循 IINRUSH+50% |
RILIM = 接地短路 | 6.5 | A | ||
| RILIM = 30kΩ | 6 | A | ||||
| RILIM = 60kΩ | 3 | A | ||||
| RILIM = 90kΩ | 2 | A | ||||
| RILIM = 120kΩ | 1.5 | A | ||||
| RHiZ | 浪涌模式選擇。 | COD/Inrush 引腳上的下拉電阻器。 外部電阻器的值,如果高于該值,則選擇浪涌模式。 | 1 | MΩ | ||
| tCOD_DIS | 截止延遲禁用閾值 | 外部電阻器的值,低于該值時(shí)將禁用截止功能 | 20 | kΩ | ||
| tCOD | 截止延遲 通過(guò)外接電阻器 RCOD 接地進(jìn)行調(diào)節(jié) 遵循 RCOD[kΩ]/120 ±15%(60kΩ ≤ RCOD ≤ 240kΩ) |
RCOD = 60kΩ | 0.4 | 0.5 | 0.6 | ms |
| RCOD = 120kΩ | 0.8 | 1 | 1.2 | ms | ||
| RCOD = 180kΩ | 1.2 | 1.5 | 1.8 | ms | ||
| RCOD = 240kΩ | 1.6 | 2 | 2.4 | ms | ||
| tINRUSH | 浪涌模式持續(xù)時(shí)間 | COD/INRUSH 引腳未連接 | 10 | ms | ||
| tRETRY | 過(guò)流保護(hù)重試時(shí)間 通過(guò)外接電阻器 RCOD 接地進(jìn)行調(diào)節(jié) 遵循 32*tCOD ±15%(60kΩ ≤ RCOD ≤ 240kΩ) |
RCOD = 60kΩ | 15.5 | ms | ||
| RCOD = 120kΩ | 31 | ms | ||||
| RCOD = 180kΩ | 46.5 | ms | ||||
| RCOD = 240kΩ | 62 | ms | ||||
| TTSD | 熱關(guān)斷溫度 | 裸片溫度 | 150 | 170 | 190 | °C |
| TTSD_HYS | 熱關(guān)斷溫度遲滯 | 40 | °C | |||
| tTSD_DG | 熱關(guān)斷抗尖峰脈沖 | 20 | μs | |||